Total Access 5000 23-Inch ANSI Chassis

Part Number:
1187001G1
CLEI:
BVM2V10G_ _


  • Provides the primary platform for distribution of high speed subscriber services
  • Consists of two Switch Module slots (SM A and SM B), a System Controller Module slot (12/SCM) slot, and 22 module slots (1 to 11) and (13 to 22)

Software
Contact your sales representative for information regarding software

Accessories
Blank Face Plate

Part Number: 1187920L1    
Part Number: 1187922E1    
  • Dual slot
Part Number: 1187925G1    
  • Covers one module slot on the rear of the Total Access 5000 chassis
Part Number: 1187921L1    
Part Number: 1187920E1    
Part Number: 1187921E1    
  • Single slot
Cable / Fiber Management

Part Number: 1187940G1 CLEI: BVMYABDK_ _  
  • Replaces the standard fiber tray on a Total Access 5000 Chassis (P/N 1187001L1 or 1187001G1)
  • Increases the number of fibers that can be routed on a chassis
Part Number: 1187940G2 CLEI: BVMYABUK_ _  
  • Mounts to the front and immediately below the Total Access 5000 Chassis
  • Increases the number of fibers that can be routed on a Total Access 5000 Chassis
  • Provides a 3RU closed baffle with filter holder
  • Allows for the management of up to 330, 1.6 millimeter fibers, or 200, 2.0 millimeter fibers per side
Cables

Part Number: 11961000JL100    
  • 32-pair, 26 AWG cable with "Cat-5 type" twist for high bit rate applications
  • Has a male champ connector on one end and an unterminated stub on the other
  • Intended for use with Total Access 5000 modules which have "Cat5 type" champ terminations, as opposed to conventional champ terminations
Part Number: 11961000JL150    
  • 32-pair, 26 AWG cable with "Cat-5 type" twist for high bit rate applications
  • Has a male champ connector on one end and an unterminated stub on the other
  • Intended for use with Total Access 5000 modules which have "Cat5 type" champ terminations, as opposed to conventional champ terminations
Part Number: 11961000JL050    
  • 32-pair, 26 AWG cable with “Cat-5 type” twist for high bit rate applications
  • Has a male champ connector on one end and an unterminated stub on the other
  • Intended for use with Total Access 5000 modules which have “Cat5 type” champ terminations, as opposed to conventional champ terminations
Part Number: 1187951G3    
Part Number: 1187951G4    
Part Number: 1187951G1    
Part Number: 1187951G2    
Part Number: 11961002JL    
  • 32-pair, 26 AWG cable with a "Category 5" (CAT 5) type twist for high bit rate applications
  • Has a 64-pin male champ connector on one end and a 64-pin female champ connector on the other end
  • Supported part numbers and cable lengths:
    • 11961002JL025 - 32-Pair Tight Twist Champ Cable, 25 ft
    • 11961002JL050 - 32-Pair Tight Twist Champ Cable, 50 ft
    • 11961002JL075 - 32-Pair Tight Twist Champ Cable, 75 ft
    • 11961002JL100 - 32-Pair Tight Twist Champ Cable, 100 ft
    • 11961002JL125 - 32-Pair Tight Twist Champ Cable, 125 ft
    • 11961002JL150 - 32-Pair Tight Twist Champ Cable, 150 ft
    • 11961002JL175 - 32-Pair Tight Twist Champ Cable, 175 ft
    • 11961002JL200 - 32-Pair Tight Twist Champ Cable, 200 ft
Part Number: 1187952G1    
  • A single 15-foot, 100-Pair cable
  • Supports up to three Total Access 5000 ADSL2+ 32-Port Access Modules or three Splitter ADSL2+ 32-Port Access Modules
Part Number: 1187952G2    
  • A single 15-foot, 100-Pair cable
  • Supports up to three Total Access 5000 ADSL2+ 32-Port Access Modules or three Splitter ADSL2+ 32-Port Access Modules
Part Number: 1187953G1    
  • One 15-foot, 100-Pair cable
  • Supports up to four Total Access 5000 Combo A2+ 24-Port, RPOTS 24- Port, or Combo V2 24-Port Access Modules
Part Number: 11961002HL    
  • 32-pair, 26 AWG cable with a "Category 3" (CAT 3) type twist
  • Intended for Total Access 5000 Central Office (CO) DSLAM applications that utilize the 32-port CAT 5 splitter card
  • Supported part numbers and cable lengths:
    • 11961002HL025 - 32-Pair Champ Cable, 25 ft
    • 11961002HL050 - 32-Pair Champ Cable, 50 ft
    • 11961002HL075 - 32-Pair Champ Cable, 75 ft
    • 11961002HL100 - 32-Pair Champ Cable, 100 ft
    • 11961002HL125 - 32-Pair Champ Cable, 125 ft
    • 11961002HL150 - 32-Pair Champ Cable, 150 ft
    • 11961002HL175 - 32-Pair Champ Cable, 175 ft
    • 11961002HL200 - 32-Pair Champ Cable, 200 ft
Connectors and Adapters

Part Number: 1184017G2    
  • Passive optical multiplexer/ demultiplexer for Coarse Wavelength Division Multiplexing (CWDM) applications
  • Multiplexes/demultiplexes up to four CWDM wavelengths plus 1310 nm over a single fiber
Fan, Filter and Housings

Part Number: 1187080G2 CLEI: BVC1ACPE_ _  
  • Consists of a sheet metal tray that holds eight 120 mm fans rated at a nominal -48 VDC
  • Mounted from the front of the rack and is installed into the top slot of the Total Access 5000 23-Inch Chassis (P/N 1187001G1) that is at Revision F or later
  • Designed to provide top exhaust, forced air ventilation to cool a fully populated chassis in applications where airflow exhaust from the top of the chassis is allowed
Part Number: 1187081G1    
  • Used in conjunction with the Fan Module to provide forced filtered air ventilation for the Total Access 5000 Chassis and components
Part Number: 1187080G3 CLEI: BVC1ABRE_ _  
  • Consists of a sheet metal tray that holds four fans rated at a nominal -48 VDC
Mounting Bracket

Part Number: 1187070F1    
  • Used to mount a Total Access 5000 Chassis in a standard 19-Inch EIA relay rack by rotating it 90 degrees
Other

Part Number: 1187071F1    
  • A transparent plastic shield that attaches to the front of the Total Access 23-Inch Chassis
  • It provides a protective shield for dense, fiber managed deployments
  • Can mount to either of the following 22-slot chassis’:
    • Total Access 5000 23-Inch Chassis, P/N 1187001G1
    • Total Access 5000 23-Inch Chassis, P/N 1187001L1*
* This part number is no longer shipping; it is simply listed here to indicate that 1st generation chassis’ are also supported.
Rackmount Brackets & Mounting Hardware

Part Number: 1200469L1    
  • 19-inch bars allow up to ten units to be mounted into a 19-inch rack
  • Used in conjunction with OCU 45 Vertical Mounting Brackets
  • Used in conjunction with Total Access 5000 Vertical Mounting Brackets
SFPs

Part Number: 1442707Gx    
  • Part numbers 1442707G1 - 1442707G44
  • Full duplex serial electric, serial optic device with both transmit and receive functions contained in a single module
  • Operates on various optical channels. Refer to product documentation for part numbers, channels, and wave lengths that are supported
Part Number: 144298XGX    
  • Full duplex serial electric, serial optic device with both transmit and receive functions contained in a single module
  • Supports operations over a wide temperature range, and are suitable for use in outside plant environments
  • Provides a high speed serial link at 10 Gbps to support SONET/SDH, Ethernet, OTN and Fiber Channel
  • Operates on various optical channels
Part Number: 144298XGXC    
  • Small Form-Factor Pluggable Long Reach 10 GigE LR-2 DWDM 80 km Extended Temperature XFP is a full duplex serial electric, serial optic device with both transmit and receive functions contained in a single module
Part Number: 1442300G1 CLEI: SOOTAK9J_ _  
  • Copper SFP that plugs into an ADTRAN GigE Copper interface designed to accept SFPs
  • Provides a 10/100/1000 Mbps full duplex data-link
Part Number: 1442971Gx    
Part number Wavelength (nm) CLEI
1442971G1 1471 BVL3A1JDAA
1442971G2 1491 BVL3A1KDAA
1442971G3 1511 BVL3A1LDAA
1442971G4 1511 BVL3A1MDAA
1442971G5 1551 BVL3A1NDAA
1442971G6 1571 BVL3A1PDAA
1442971G7 1591 BVL3A1RDAA
1442971G8 1611 BVL3A1SDAA
Part Number: 1442390G1 CLEI: BVL3AFGD_ _  
  • Single-mode fiber SFP that plugs into ADTRAN Gigabit Ethernet modules designed to accept SFPs
  • Designed for use in Dense Wavelength Division Multiplexing (DWDM) applications
Part Number: 1442390G2 CLEI: BVL3AFHD_ _  
  • Single-mode fiber SFP that plugs into ADTRAN Gigabit Ethernet modules designed to accept SFPs
  • Designed for use in Dense Wavelength Division Multiplexing (DWDM) applications
Part Number: 1442912FX    
  • Part number: 1442912F1, TX Wavelength: 1320-1340nm, RX Wavelength: 1260-1280nm, CLEI: BVL3A1CD__
  • Part number: 1442912F2, TX Wavelength: 1260-1280nm, RX Wavelength: 1320-1340nm, CLEI: BVL3A1DD__

  • Plugs into ADTRAN equipment designed to accept Extended Form factor Pluggables (XFPs)
  • Provides a 10 G optical interface to the supporting system

Part Number: 1442922FX    
  • Part number: 1442922F1, TX Wavelength: 1320-1340nm, RX Wavelength: 1260-1280nm, CLEI: BVL3A1ED__
  • Part number: 1442922F2, TX Wavelength: 1260-1280nm, RX Wavelength: 1320-1340nm, CLEI: BVL3A1FD__

  • Plugs into ADTRAN equipment designed to accept Extended Form factor Pluggables (XFPs)
  • Provides a 10 G optical interface to the supporting system

Part Number: 1442942FX    
  • Part number: 1442942F1, TX Wavelength: 1320-1340nm, RX Wavelength: 1260-1280nm, CLEI: BVL3A1GD__
  • Part number: 1442942F2, TX Wavelength: 1260-1280nm, RX Wavelength: 1320-1340nm, CLEI: BVL3A1HD__

  • Plugs into ADTRAN equipment designed to accept Extended Form factor Pluggables (XFPs)
  • Provides a 10 G optical interface to the supporting system

Surge Protection

Part Number: 1192PP168VLx    
  • Designed to protect the associated Total Access 5000 Chassis and components by shunting to ground lightning strike surges or other electrical surges seen on any of the customer loops
  • Supported Part Numbers:
    • 1192PP168VL1, 710 splice module
    • 1192PP168VL2, MS2 splice module
    • 1192PP168VL3, 710 splice module
    • 1192PP168VL4, MS2 splice module