The available timing modes within the TSU/TDU XX0 product line are as follows:
When a timing mode is selected, the timing source for every interface within the TSU is chosen. This includes DS-1, DSX-1, Nx56/64, OCU, and DSU. The important thing to remember about timing is that you can only have ONE SOURCE OF TIMING in the network to run without errors.
When internal timing is selected and there is no secondary interface in the TSU, the internal oscillator and frame pulse generator are used.
Note: The internal oscillator is a stratum 4 clock.
If the TSU 100 and TSU 120 are used, the base Nx56/64 is the only Nx port capable of providing timing. If you use the TSU 600 and are operating in DTE timing mode, the Nx being used must reside in slot 1.
The Nx takes the clock provided on the ETC pins on the V.35 interface and derives a T1 clock based on the number of DS0’s assigned to the port. If the external router is providing a clock that does not match the rate the Nx is expecting the T1 timing will be inaccurate and could cause the T-span not to clear alarms. To check this, set the TSU to internal timed and the alarms should clear if that is the issue.
This allows the equipment on the DSX-1 interface to provide timing to the network. This is not the same as CSU timing because the base DSX is not capable of driving a transmit frame pulse for the system. So even in this mode, if there are timing issues, you will see frame slips on the T1 interfaces.
This is essentially the same as Base DSX timing. All interfaces will derive their timing from the secondary interface modules timing. If the secondary interface is unplugged, the T1 framer on that interface will continue to generate timing for the system.
This mode makes the TSU appear transparent to timing. That is, the Secondary interface transmitter will use the receive timing from the Network interface and the Network interface transmitter will use the receive timing from the Secondary interface. Since the framing is also passed in the same manner, data will pass through transparently. If there is a timing problem in the circuit this will not fix it. It only moves the problem from our box to some other equipment (PBX or Telco). Figure 1 illustrates the framing and timing for CSU timing.
This is not an option visible from the front panel, but if a multi-port DBU module goes into backup, the whole system gets timed from the backup link. If the DBU is misconfigured for the wrong number of DS0’s versus what the backup link provides, you may see the backup work properly but the T1 will never come back. This is because the timing on the T1 could be out of specification due to the incorrect timing on the backup link.
Note: On units with the CSU timing option, you do not have to set the timing on the SI module.
If you experience any problems using your ADTRAN product, please contact ADTRAN Technical Support.
|
ADTRAN provides the foregoing application description solely for the reader's consideration and study, and without any representation or suggestion that the foregoing application is or may be free from claims of third parties for infringement of intellectual property rights, including but not limited to, direct and contributory infringement as well as for active inducement to infringe. In addition, the reader's attention is drawn to the following disclaimer with regard to the reader's use of the foregoing material in products and/or systems. That is: ADTRAN SPECIFICALLY DISCLAIMS ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL ADTRAN BE LIABLE FOR ANY LOSS OR DAMAGE, AND FOR PERSONAL INJURY, INCLUDING BUT NOT LIMITED TO, COMPENSATORY, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR OTHER DAMAGES. |