OPTI-3 Controller Module 1550NM

The OCM provides three electrical DS3 drops from a single or redundant OC-3 interface when used with an OPTI-3 chassis. The OCM may be installed in either a rackmount chassis or a wallmount chassis.

The OCM features include the following:

  • SONET OC-3 LR-1 optical interface
    - Rate: 155.52 Mb/s
    - Span length: Long Reach, 40 km
    - Wavelength: 1550 nm (nominal)
  • Dual SC optical connections
  • Framing, multiplexing and mapping compliant with SONET standards
  • OC-3 facility and equipment loopback
  • Detects and indicates standard optical and SONET related alarms and conditions
  • SONET level performance monitoring
  • SONET line protection switching
  • 1+1 equipment and facility protection for optical network interface
  • 1:1 equipment protection for optical network interface
  • Maximum 60 ms protection switching time (OC-3 to low speed interface)
  • Board-mounted manual APS control switch
  • Clear Channel DS3 signals (via BNC connectors)
  • Two external DS1 BITS clock interfaces
  • Three sense points including AUX1, AUX2, and AUX3
  • Fully hot swappable
  • External BITS, line, or free-run timing modes
  • SONET Minimum Clock (SMC) with ±20 ppm accuracy
  • OAM&P via data communication over Section DCC channel
  • Support SONET section DCC bridging
  • OSI/IP Tunneling
  • Controller cards Cross Copy Communication Link
  • OAM&P interface via craft interface (DB-9)
  • TL1, Telnet, SNMP, and TFTP over Ethernet
  • Local software downloads via craft interface (DB-9) and TFTP over Ethernet or OSI Tunnel
  • TL1 management support
  • Supports TL1-based GUI network management interface
  • Three DS3 interfaces
  • Software-controlled DS3 transmit level control
  • Automatic receive equalization
  • Software-controlled remote and local DS3 loopback capability
  • Monitors incoming receive signal for Loss Of Signal (LOS)
  • Monitors the receive analog and digital LOS
  • Monitors transmit output signal for drive failure
  • LED status indicators:
    - Board Status (Power/Fail)
    - Optic Status (LOL, LOF, etc.)
    - DS3 #1 Status
    - DS3 #2 Status
    - DS3 #3 Status
    - ACO
  • External ACO input (RMC only)
  • Three audible alarm outputs including critical, major, and minor (RMC only)
  • Three visual alarm outputs including critical, major, and minor (RMC only)
  • –20 VDC to –60 VDC input voltage range
  • +20 VDC to +60 VDC input voltage range
  • Power consumption between 7 and 10 watts (typical) per OCM
  • Operating temperature range of –40°C to +65°C (installed in RMC)
  • Operating temperature range of –40°C to +50°C (installed in WMC)
  • Relative humidity up to 95%, noncondensing
  • Storage temperature range –40°C to +85°C
  • NEBS Level 3, GR-1089-CORE, GR-63-CORE, and UL60950 compliant
  • Meets applicable optical and SONET standards (GR-253, T1.101, T1.105.xx)


    


Name Part Number CLEI Description
OPTI-3 Controller Module 1550NM 1184002L6 SOUCABMJ_ _ OPTI-3 Controller (1550nm)